  single output model selection model output adjustment convection forced air line load ripple & noise initial setting voltage range cooled current current (note 3) regulation regulation %p-p (note 1) accuracy map140-1012 12v/15v 11.0v to 16.0v 9.2/7.3a (note 2) 12.5a/10a (note 2) 0.1% 0.5% 1% 11.97v to 12.03v map140-1024 24v/28v 22.8v to 29.2v 4.6/4a (note 2) 6.3a/5.4a (note 2) 0.1% 0.5% 1% 23.95v to 24.05v MAP140-1048 48v 45.6v to 54.0v 2.3a 3.1a 0.1% 0.5% 1% 47.9v to 48.1v notes: 1) maximum peak to peak noise expressed as a percentage of output voltage, 20mhz bandwidth. 2) map140-1012 output currents are expressed as 12v/15v operation. map140-1024 output currents are expressed as 24v/28v operat ion. 3) with 200 lfm forced air cooling. features ? rohs lead-solder-exemption compliant ? universal input 85-264 vac ? input transient & esd compliance to en61000-4-2/-3/-4 ? ce marked to low voltage directive ? industry-standard footprint: 7.00" x 4.30" x 1.80" (177.8mm x 109.2mm x 45.7mm) ? remote sense and overvoltage protection ? power fail signal standard on map140-3000p, optional on map140-1012 and map140-1024 ? optional overtemperature protection, l-bracket, and cover multiple output model selection 80w convection cooled, 140w forced-air cooled (200 lfm) model output adjustment output peak output line load ripple & noise initial setting voltage range current (note 1) current (note 1) regulation regulation %p-p (note 2) accuracy +5v 4.75 - 5.25v 16a/25a 20a/25a pk 0.2% 1% 1% 5.09v to 5.11v map140-3000p +12v fixed 4a/9a pk 4a/9a pk 0.1% 2% 1% 11.97v to 12.03v -12v fixed 1a/1.5a pk 1a/1.5a pk 0.1% 2% 1% -11.4v to -12.6v notes: 1) peak loads up to 140 watts for 60 seconds or less are acceptable, (10% duty cycle max.). peak power must not exceed 140 wa tts. 2) maximum peak to peak noise expressed as a percentage of output voltage, 20mhz bandwidth. map140 ac-dc series data sheet mcd10167 rev. 1.0, 04-jun-10 page 1 of 4 www.power-one.com power-one?s map140 series provides a full range of options and up to 30 watts more power than comparable products in this industry-standard footprint. with a universal input from 85 to 264 vac and power densities up to 2.6 watts/inch3, the map140 meets the most rigorous requirements of commercial, industrial, and datacom systems. rated for use in convection and forced-air cooled (200 lfm) applications, the map140 delivers dependable power with a mean time between failures (mtbf) in excess of 180,000 hours. in addition to ul, csa, and tv regulatory compliance, the map140 displays the ce mark. description model numbers highlighted in yellow or shaded are not recommended for new designs.
input specifications parameter conditions/description min nom max units input voltage - ac continuous input range. 85 264 vac input frequency ac input. 47 63 hz brown out protection lowest ac input voltage that regulation is maintained with full rated loads. 85 vac hold-up time nominal ac input voltage (110 vac) 110 watt load: 20 ms 140 watt load: 16 input current 85 vac (140w load). 2.5 a rms 110 vac (140w load). 2.0 input protection non-user serviceable internally located ac input line fuse. inrush surge current internally limited by thermistor. vin = 264vac (one cycle). 25c. 41 a pk operating frequency switching frequency of main transformer. 22 khz output specifications parameter conditions/description min nom max units efficiency full load, 110 vac. varies with distribution of loads among outputs. 65 70 80 % minimum loads single output models. 0 amps map140-3000p, total output current of v1 + v2 (note 1). 2 ripple and noise full load, 20mhz bandwidth. see model selection chart. output power single output models. see model selection chart. map140-3000p with convection cooling. 80 watts map140-3000p with 200 lfm forced air cooling. 140 overshoot / undershoot output voltage overshoot/undershoot at turn-on/turn-off. 0 v regulation varies by output. total regulation includes: line changes from 90-132 vac or 175-264, see model selection chart. changes in load starting at 20% load and changing to 100% load. transient response recovery time, to within 1% of initial set point due to a 50-100% 500 s load change, 4% max. deviation. turn-on delay time required for initial output voltage stabilization. map140-3000p 1 sec single output models 2 turn-on rise time time required for output voltage to rise from 10% to 90%. 20 ms notes: 1) minimum load is required only to meet the regulation limits of v3. interface signals and internal protection parameter conditions/description min nom max units overvoltage protection provided on single output models map140-3000p, v1 6.1 7.2 and v1 of map140-3000p. map140-1012 17.3 20.2 v map140-1024 32.2 37.8 MAP140-1048 55.2 64.8 overload protection fully protected against output overload and short circuit. automatic recovery upon removal of overload cond ition. remote sense voltage drop compensated for at the load. 250 mv input power fail ttl compatible logic signal. time before regulation dropout due warning to loss of input power at 140 watts, 110 vac. standard on map140-3000p 2.3 ms and optional on map140-1012. overtemperature protection optional signal provides system shutdown due to excessive internal temperature. see options. map140 ac-dc series data sheet mcd10167 rev. 1.0, 04-jun-10 page 2 of 4 www.power-one.com
safety, regulatory, and emi specifications parameter conditions/description min nom max units agency approvals ul1950. csa 22.2 no. 234/950. approved en60950 (tv). dielectric withstand voltage input to output, 1 second. 2600 vdc electromagnetic fcc cfr title 47 part 15 sub-part b - conducted & radiated. b class interference, conducted en55022 / cispr 22 conducted. b esd susceptibility per en61000-4-2, level 4. 8 kv radiated susceptibility per en61000-4-3, level 3. 10 v/m eft/burst per en61000-4-4, level 3. 2 kv input transient protection per en61000-4-5, class 3. line to line 1 kv line to ground 2 insulation resistance input to output. 10 m  leakage current per en60950, 264vac. 110 vac 0.5 ma 264 vac 1.5 environmental specifications parameter conditions/description min nom max units altitude operating. 10k asl ft. non-operating. 40k asl ft. operating temperature derate linearly above 50c by 2.5% per c at 100% load: 0 50 c at 50% load: 0 70 c storage temperature -40 85 c temperature coefficient 0c to 70c (after 15 minute warm-up period). 0.02 0.05 %/c relative humidity non-condensing. 95 %rh shock operating, peak acceleration. 20 g pk vibration random vibration, 10hz to 2khz, 3 axis. 6 g rms options description notes dimensions l-bracket add ?l? suffix to model number. 7.19" x 4.50" x 2.40" (182.6mm x 114.3mm x 61.0mm) cover add ?c? suffix to model number. includes l-bracket. 7.19" x 4.50" x 2.40" for convection cooled applications, derate output power to 75 watts, maximum. (182.6mm x 114.3mm x 61.0mm) power fail signal add ?p? suffix to model number. provides 2.3ms warning time before main output drops 5%. warning time increases at reduced load levels. option available only n/a on map140-1012 and map140-1024. power fail is standard on map140-3000p. thermal shutdown add ?t? suffix to model number. initiates shut-down in the event of an overtemperature n/a condition. automatic recovery. where available, power fail signal is initiated prior to shutdown. map140 ac-dc series data sheet mcd10167 rev. 1.0, 04-jun-10 page 3 of 4 www.power-one.com
note 1 overall size: 7.00" x 4.30" x 1.97" (177.8mm x 109.2mm x 50.0mm) overall weight: 1.3 lb (0.59 kg) contact factory for dimensions for l-bracket and cover. map140 ac-dc series data sheet mcd10167 rev. 1.0, 04-jun-10 page 4 of 4 www.power-one.com nuclear and medical applications - power-one products are not designed, intended for use in, or authorized for use as critical c omponents in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written conse nt of the respective divisional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of MAP140-1048

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X